DATA & Technology
Protecting Uptime.
Controlling Noise.
Advanced acoustic and vibration solutions engineered for 24/7 data environments that protect equipment, ensure uptime, safeguard staff, and comply with community ordinances.

Quiet Power for the Digital World.
Running a data or technology facility means balancing relentless uptime with complex mechanical demands. Cooling towers, backup generators, and server halls hum around the clock, and while that sound may seem like “business as usual,” it often brings real problems.
That’s where Memtech comes in. We act as a partner bringing measured diagnostics, predictive modeling, and turnkey design/build solutions that quiet the noise without compromising performance. From acoustic enclosures and silenced HVAC intakes to vibration-isolated floors and compliance-ready reporting, we deliver solutions that are engineered to work in the real world of 24/7 operations.
That’s where Memtech comes in. We act as a partner bringing measured diagnostics, predictive modeling, and turnkey design/build solutions that quiet the noise without compromising performance. From acoustic enclosures and silenced HVAC intakes to vibration-isolated floors and compliance-ready reporting, we deliver solutions that are engineered to work in the real world of 24/7 operations.
- Vibration undermines sensitive hardware, threatening drive stability, error rates, and long-term reliability.
- Cooling and generator noise carries into surrounding neighborhoods, triggering community complaints and regulatory scrutiny.
- Sustained equipment noise strains your staff, impacting focus, productivity, and hearing safety.
We understand what’s at stake: downtime isn’t an option, compliance isn’t negotiable, and trust with your community matters.
Common Challenges We Help Solve.
Persistent low-frequency hum from chillers and cooling towers.
Structural vibration from heavy equipment disrupting sensitive hardware.
Airflow noise from HVAC intakes/exhaust affecting technical zones.
External community noise exposure from rooftop generators.
Emergency and load-bank testing producing noise spikes that exceed local ordinances.
High baseline noise levels impacting worker focus and hearing health.

Data & Technology
Where Technology & Acoustics Work in Harmony
- Protect Sensitive Equipment & Uptime
Vibration can disrupt hard drives, precision sensors, and high-density servers, leading to data errors or downtime. - Maintain Regulatory Compliance
Exterior cooling systems, chillers, and emergency generators often exceed municipal noise limits; engineered barriers prevent violations and penalties. - Create Healthy Work Environments
Continuous noise from servers and HVAC systems can exceed 85–90 dB(A), requiring OSHA-compliant monitoring and mitigation to protect staff. - Support Future-Proof Operations
Proactive design during build-out or expansion prevents costly retrofits and ensures facilities meet growing density and cooling demands. - Prevent Community Complaints
Rooftop and perimeter equipment can transmit noise into residential and commercial districts, creating reputational risk and delays in permitting. - Improve Energy Efficiency
Poorly designed mitigation can restrict airflow and force cooling systems to work harder. Engineered silencers and barriers reduce noise while maintaining airflow efficiency.

Data & Technology
Our Approach & Capabilities
We design and deliver robust acoustic and vibration solutions for 24/7 data center operations. Our capabilities include advanced floating floor systems, vibration isolation mounts, acoustic enclosures and barrier walls, and ventilation silencers tailored for airflow performance. We conduct on-site noise and vibration surveys, followed by predictive modeling to validate expected outcomes. All projects are backed by full RT, STC, and vibration transfer testing, ensuring your facility achieves quieter, more stable operations while adhering to regulatory boundaries.
Our approach:
- Measured & Modeled
We start with Class 1 acoustic and vibration logging, broadband and octave-band analysis to accurately map the root cause. - Tailored Engineering
Whether it’s floating floors, vibration isolators, acoustic enclosures, or airflow-quieting silencers, our designs are built to meet your site's layout, equipment, and performance needs. - Turnkey Delivery
From engineering and fabrication to fully managed installation and post-install validation, we deliver a single-source solution that ensures seamless project execution. - Compliance & Assurance
Our final deliverables include comprehensive performance reporting suitable for OSHA, environmental regulators, and building inspectors.
Three Ways to Work With Us

Full-Service Implementation
We handle the entire process, from diagnostics and reporting to procurement and installation.

Product Solutions with Expert Support
Looking for a specific product?Explore acoustic panels, vibration mounts, enclosures, and more.

Self-Guided Solutions
Product sheets and specs for self-implementation.

Why Choose Memtech Acoustics
Certified and Licensed Professionals
Testing conducted by engineers and acoustic specialists, not general contractors or “safety consultants”.
National Standards Alignment
We follow OSHA 1910.95, NIOSH criteria, and ANSI S12.19-1996 methods for exposure assessment.
Engineering Expertise
Your results are reviewed by professionals who understand both compliance and the physics behind the numbers.
Mitigation-Ready Data
If your site needs acoustic control, we already have the frequency analysis and location-specific insights to design an effective solution.
Confidential & Detailed Reporting
We don’t just drop a spreadsheet. You get full documentation, delivered in easy-to-understand language with visuals and defensible insights you can act on.
Frequently Asked Questions (FAQs)
What are the primary noise and vibration sources in data centers?
The most common contributors are cooling towers, chillers, CRAC/CRAH units, pumps, and backup generators. These systems produce a mix of low-frequency tonal noise and structural vibration that can affect both employees and sensitive IT hardware.
Can vibration really affect servers and storage equipment?
Yes. Research and field studies show that low-frequency vibration can impact hard disk drives and other precision electronics, leading to errors, latency, and reduced hardware life. Even small vibration amplitudes can be problematic in high-density racks.
How do you measure and evaluate noise in these environments?
We use Class 1 sound level meters and long-term data logging to capture real operating conditions, paired with octave- and narrow-band frequency analysis to pinpoint tonal noise sources. For vibration, we deploy triaxial accelerometers to measure transfer paths through slabs, racks, and supporting structures.
What standards or guidelines do your solutions align with?
We design and report in alignment with OSHA 29 CFR 1910.95 (occupational noise exposure), ISO 1996 (environmental noise), ASHRAE design recommendations for data centers, and ASTM/ISO standards for sound transmission and absorption. Documentation can also be prepared for local municipal noise ordinances and environmental permitting.
What mitigation strategies are effective for data center equipment noise?
Common strategies include acoustic barrier walls around cooling equipment, silencers for HVAC airflow paths, floating floor systems to isolate structural vibration, damping treatments for enclosures, and resilient isolation mounts for mechanical equipment. Each site requires a tailored design based on measured conditions.
How do you ensure that noise barriers or enclosures don’t interfere with airflow and cooling?
We work with mechanical and facilities engineers to integrate silencers, louvers, and enclosure designs that maintain required airflow, pressure drop limits, and heat rejection performance while reducing noise. Acoustic control must never compromise thermal reliability.
How long do these systems last in outdoor/industrial conditions?
Our specified systems typically provide 20–40+ years of service life, using UV-stable, weather-resistant, fire-rated, and corrosion-protected materials. Durability is critical for 24/7 facilities with no tolerance for downtime.
Ready for answers? Let’s talk.

Let's Get Started. Contact Us.
Talk to our engineers. We’ll assess your needs and recommend a solution that works for your project.