Close-up of dark gray acoustic foam panels with pyramid-shaped protrusions arranged in a grid pattern.

Henry Ford Health System

Industry:
Healthcare
,
Application:
Acoustic Panel Installation
,
Ceiling Baffle System
,
Commercial Noise Control
,
Memtech Acoustics designed and supplied 56 hanging baffles for four team work areas and a sound barrier above the exam room ceilings at Henry Ford Health System's West Bloomfield Medical Center, then coordinated the installation in November 2020.
West Bloomfield, MI

Year

2020

Ceiling baffles

56

Team work areas treated

4

Barrier above exam rooms

12 rolls

Services Provided:

Site Evaluation, Treatment Design, Layout Drawings, Product Supply, Installation Coordination

Challenge

Henry Ford Health System contacted Memtech Acoustics through its website. The project, at the West Bloomfield Medical Center on Farmington Road in West Bloomfield, Michigan, covered two kinds of space.

The first was a set of four team work areas, two of which have ceilings about 18 feet high. The second was the clinic's exam rooms, which have drop ceilings 8 to 9 feet high. Memtech visited the clinic in July 2020 and again in October 2020.

Solution

For the team work areas, Memtech estimated the sound absorption each room needed from its dimensions and volume. It then prepared a layout drawing for each area that set where each baffle hangs and at what height. In one area, the drawing set three rows of baffles at staggered heights between 12 and 16 feet, below a ceiling that rises from 16 feet 8 inches to 18 feet 2 inches.

The design called for 56 white acoustic baffles, each 24 by 48 inches and 2 inches thick, hung vertically from the ceiling. Absorption placed high in a tall room takes up sound that would otherwise reflect off the ceiling and upper walls back into the work area.

For the exam rooms, Memtech supplied 12 rolls of 1/8 inch mass-loaded vinyl barrier, each 54 inches by 60 feet, to lay above the drop ceilings. The barrier adds a blocking layer across the space above the ceiling tiles, a common path for conversation to travel between rooms.

Both treatments went into the existing ceilings, with no wall or layout changes. Memtech supplied the materials and coordinated the installation, which needed a lift to reach the high ceilings in the team work areas.

Results

Installation of both treatments finished in November 2020: the baffles in the four team work areas and the barrier above the exam room ceilings.

In October 2021, the health system's regional facilities supervisor asked Memtech to quote another project at the same clinic.

Facing a similar challenge?

Every project starts with a conversation. Tell us about your space and we will outline your options.

Start the Conversation

Did you know? Most listeners hear a sound 10 dB lower as about half as loud. Hear the difference for yourself.

Listen to Sound Demos →

Related Projects

Michigan Association of Conservation Districts

The Michigan Association of Conservation Districts experienced reverberation as high as 4.0 seconds in the open meeting room at its Allegan office, a room used for board meetings and workshops. This level far exceeds a desired level for clear communication for meeting facilities. Memtech Acoustics evaluated the space and engineered a wall and ceiling panel layout modeled to bring reverberation under 1.0 second, significantly improving the acoustic characteristics of the room.
Read Case Study

Sylvan Lake Community Center

The Sylvan Lake Community Center's multipurpose room seats up to 150 for events, ceremonies, and film showings, but its vaulted ceiling and hard surfaces pushed reverberation to 1.9 seconds, well past the point where speech stays clear. Memtech Acoustics measured the room and engineered a ceiling and wall panel layout modeled to bring it to a 1.0 second target.
Read Case Study

Apostolic Christian Church of Livonia

The dining hall at Apostolic Christian Church of Livonia grew hard to talk in when the room filled for gatherings of up to eighty people. Memtech Acoustics measured reverberation at 0.8 seconds, above the range a shared meal and conversation call for. Memtech engineered a wall panel and ceiling tile layout and confirmed by measurement that reverberation dropped to between 0.5 and 0.6 seconds.
Read Case Study
Modern open office with blue acoustic ceiling baffles designed to absorb sound and reduce workplace noise.

Let's Get Started. Contact Us.

Talk to our experts. We’ll assess your needs and recommend a solution that works for your project.