Reverb Control
,
A restaurant in Shelby Township, Michigan wanted to address the noise in its two dining rooms. Memtech Acoustics measured reverberation above 1.8 seconds in the main dining room and above 1.5 seconds in the back room, against a 1.1 second target, and used the data to size the ceiling treatment the owners then ordered.
Shelby Township, MI
Dining room of a Shelby Township restaurant under an exposed metal roof deck, photographed during Memtech Acoustics' reverberation study

Year

2026

Reverberation (main dining)

above 1.8 s

Design target

1.1 s

Ceiling panels ordered

114

Services Provided

RT60 Assessment, Reverberation Modeling, Ceiling Treatment Layout, Written Reverberation Summary, Material Supply

Challenge

A restaurant in Shelby Township, Michigan has two dining rooms under an exposed metal roof deck, with hard, reflective finishes throughout. The owners wanted to address the noise. Memtech Acoustics measured first, so the treatment would be sized from data, and kept the scope to a basic reverberation study.

Solution

In July 2026, Memtech measured reverberation time (RT60) in both rooms using an impulse source and measurement microphones. Reverberation exceeded 1.8 seconds in the main dining room and 1.5 seconds in the back dining room. The desired range for restaurants is 0.8 to 1.1 seconds, and Memtech set a target of 1.1 seconds for both rooms.

A parametric model built from the measured values sized the treatment to that target. Because of the artwork and fixtures on the walls, the treatment went on the ceiling: 2 by 4 foot, 2-inch open-cell foam panels, laid out room by room in a plan view. A follow-up model then sized a suspended-panel layout to the same target.

Results

The owners received a written reverberation summary with the measured values, the target, the modeled treatment, and the layout. They then ordered 114 suspended ceiling panels through Memtech, with installation by their own contractor. Installation is pending, so no post-installation result is reported.

Facing a similar challenge?

Every project starts with a conversation. Tell us about your space and we will outline your options.

Start the Conversation

Did you know? A 10 dB reduction cuts perceived noise in half. Hear the difference for yourself.

Listen to Sound Demos →

Related Projects

Michigan Association of Conservation Districts

The Michigan Association of Conservation Districts measured reverberation as high as 4.0 seconds in the open meeting room at its Allegan office, a room used for board meetings and workshops. Memtech Acoustics measured the space and engineered a wall and ceiling panel layout modeled to bring reverberation under 1.0 second so staff can hear one another clearly.
Read Case Study

Sylvan Lake Community Center

The Sylvan Lake Community Center's multipurpose room seats up to 150 for events, ceremonies, and film showings, but its vaulted ceiling and hard surfaces pushed reverberation to 1.9 seconds, well past the point where speech stays clear. Memtech Acoustics measured the room and engineered a ceiling and wall panel layout modeled to bring it to a 1.0 second target.
Read Case Study

Apostolic Christian Church of Livonia

The dining hall at Apostolic Christian Church of Livonia grew hard to talk in when the room filled for gatherings of up to eighty people. Memtech Acoustics measured reverberation at 0.8 seconds, above the range a shared meal and conversation call for. Memtech engineered a wall panel and ceiling tile layout and confirmed by measurement that reverberation dropped to between 0.5 and 0.6 seconds.
Read Case Study
Modern open office with blue acoustic ceiling baffles designed to absorb sound and reduce workplace noise.

Let's Get Started. Contact Us.

Talk to our experts. We’ll assess your needs and recommend a solution that works for your project.