Close-up of dark gray acoustic foam panels with pyramid-shaped protrusions arranged in a grid pattern.

Saint Hugo of the Hills Catholic Church

Industry:
Commercial
,
Application:
Reverb Control
,
Memtech Acoustics measured reverberation as high as 3.4 seconds in the worship space at Saint Hugo of the Hills Catholic Church in Bloomfield Hills and 2.7 seconds in its entrance, above the ranges recommended for those spaces. Memtech identified the smooth stone, tile, and drywall surfaces as the main cause and engineered a ceiling panel design modeled to reach 2.5 and 1.5 second targets.
Bloomfield Hills, MI
Worship space at Saint Hugo of the Hills Catholic Church in Bloomfield Hills, Michigan, with its sloping ceiling, stone walls, and pews, during Memtech Acoustics' reverberation study

Year

2026

Measured RT60 (worship)

3.4 s

Target RT60 (worship)

2.5 s

Ceiling panels (worship)

44

Services Provided

RT60 and C50 Assessment, Acoustic Modeling, Treatment Design

Saint Hugo of the Hills Catholic Church in Bloomfield Hills, Michigan engaged Memtech Acoustics to address reverberation in its main worship space and entrance. In a worship space, long reverberation reduces speech clarity and raises background noise.

Challenge

The worship space is a large room with a sloping drywall ceiling reaching roughly 39 feet at its peak, tiled floors, wooden benches, and stone walls with few interrupting features. Surfaces like these reflect nearly all sound energy back into the room, and the report linked them to the poor speech clarity and elevated background noise the church had experienced.

Solution

Memtech Acoustics measured reverberation time (RT60) and speech clarity (C50) in both rooms under unoccupied conditions, recording at four microphone positions in the worship space and two in the entrance across octave bands from 125 to 4,000 Hz. Reverberation reached 3.4 seconds in the worship space and 2.7 seconds in the entrance, with C50 values of 4.7 dB and 1.6 dB. The measurements confirmed that the smooth stone, tile, and drywall surfaces were the primary cause.

Because covering the windows and doors was not a viable option and treatment had to preserve the room's aesthetics and function, treatment was concentrated on the ceiling. Using a parametric model built from the measured data and the absorption performance of the specified materials, Memtech sized the coverage to the target rather than distributing panels arbitrarily. The worship-space design specified 44 four-foot-square, four-inch-thick open-cell foam panels rated NRC 1.04, with the thickness selected to absorb the low-frequency energy that dominated the measurements. The entrance was addressed with a companion two-inch panel layout.

Results

The engineered design was modeled to bring the worship space to a 2.5 second reverberation target and the entrance to 1.5 seconds. The design has not been installed, so the modeled results have not been confirmed by measurement.

Facing a similar challenge?

Every project starts with a conversation. Tell us about your space and we will outline your options.

Start the Conversation

Did you know? A 10 dB reduction cuts perceived noise in half. Hear the difference for yourself.

Listen to Sound Demos →

Related Projects

Michigan Association of Conservation Districts

The Michigan Association of Conservation Districts measured reverberation as high as 4.0 seconds in the open meeting room at its Allegan office, a room used for board meetings and workshops. Memtech Acoustics measured the space and engineered a wall and ceiling panel layout modeled to bring reverberation under 1.0 second so staff can hear one another clearly.
Read Case Study

Sylvan Lake Community Center

The Sylvan Lake Community Center's multipurpose room seats up to 150 for events, ceremonies, and film showings, but its vaulted ceiling and hard surfaces pushed reverberation to 1.9 seconds, well past the point where speech stays clear. Memtech Acoustics measured the room and engineered a ceiling and wall panel layout modeled to bring it to a 1.0 second target.
Read Case Study

Apostolic Christian Church of Livonia

The dining hall at Apostolic Christian Church of Livonia grew hard to talk in when the room filled for gatherings of up to eighty people. Memtech Acoustics measured reverberation at 0.8 seconds, above the range a shared meal and conversation call for. Memtech engineered a wall panel and ceiling tile layout and confirmed by measurement that reverberation dropped to between 0.5 and 0.6 seconds.
Read Case Study
Modern open office with blue acoustic ceiling baffles designed to absorb sound and reduce workplace noise.

Let's Get Started. Contact Us.

Talk to our experts. We’ll assess your needs and recommend a solution that works for your project.