Engineering Controls for
Industrial Noise & Vibration
We Understand What's At Stake
At Memtech Acoustics, we deliver data-driven solutions that target noise at its source, helping manufacturers minimize risk and maintain operational excellence.
- Occupational hearing loss and long-term health effects
- OSHA compliance violations and costly fines
- Reduced employee focus, morale, and productivity
- Difficulties in verbal communication and task execution
- Community noise complaints and legal disputes
- Reputational harm as a poor corporate neighbor

Common Challenges We Solve.
Environmental Noise Management
Facility Communication & Productivity

Proven Engineering Controls for High-Stakes Environments
- On-site diagnostics and sound level mapping to understand the root causes.
- Systems engineering methodology to prevent trial-and-error methods.
- Custom-fabricated enclosures, barriers, silencers, and dampening systems.
- OSHA-compliant noise exposure surveys with certifiable reporting.
- End-to-end project management, from concept to validation.
- Advanced acoustic modeling to simulate solutions before implementation.
Warehousing & Fulfillment Noise & Vibration Mitigation
We offer noise exposure testing and mapping, identifying high-exposure zones in production, packing or delivery areas. From there, we design and deliver targeted controls that reduce noise at the source without disrupting workflow.
For new facilities, our team works with general contractors and architects to integrate acoustical considerations into the design. This helps avoid costly retrofits and ensures the building performs as intended from day one.
For existing operations, we offer turnkey programs that combine measurement, design, installation support, and post-install validation.
The result: a safer, more productive environment where workers can focus, supervisors can communicate, and operations meet OSHA standards with documented certification.

Integrated Engineering Controls We Deliver


Our Approach to Industrial Noise Control
We follow the hierarchy of controls and look for the fix at the source first: an enclosure, a silencer, damping, isolation, or a change to the machine itself. When a requested target cannot be met in the space available, we say so early. For SoundOff Signal's anechoic test room, the first request was performance down to 500 Hz. Our analysis showed the room's dimensions could not support it, so we designed to a 700 Hz maximum cutoff, and the finished room qualified from 562 Hz.
We verify the result by measurement. At MACI's compressor test chamber, validation testing found the test stand had not fully bonded to its concrete core. A stiffening plate was added, the chamber was retested, and it met every element of its specification.
- Exposure assessment: dosimetry and area noise mapping against OSHA 29 CFR 1910.95 and NIOSH criteria.
- Source diagnostics: frequency analysis that separates tonal sources from broadband noise.
- Engineering controls: enclosures, barriers, silencers, damping and vibration isolation specified for the source.
- Test environments: anechoic rooms, test chambers and in-process test booths.
- Validation: measurement after installation against the original target.
Our Process
2
Site Assessment
4
Fabrication & Installation*
1
Initial Consultation
3
Design & Material Selection
5
Verification & Reporting

Noise Exposure Assessment for a Packaging Room
A manufacturer needed to know where its packaging room stood against OSHA noise limits. Memtech Acoustics ran full-shift personal dosimetry and an area noise survey. Time-weighted exposures were below OSHA's 90 dBA permissible exposure limit, but 7 of 10 employees exceeded the 85 dBA action level, which requires a hearing conservation program. Frequency analysis tied the noise to specific sources, so the recommended controls target the sources themselves.
- Full-shift personal dosimetry on 10 employees, evaluated against OSHA 29 CFR 1910.95
- Area noise survey with a Class 1 sound level meter mapped levels across the plant floor
- Vacuum-pump tones at 63 and 125 Hz and a likely conveyor bearing issue at 2,500 Hz, separated from broadband weighing noise
- Source controls recommended, including barrier curtains at the pumps and a conveyor repair
Support That Scales With Your Needs
Full-Service Implementation
Collaborative Deployment
Self-Guided Solutions
Let’s Engineer the Right Solution, Together.

Integrated Design & Install Solutions We Deliver
Acoustic challenges don’t end with recommendations. Memtech Acoustics' Design & Install services combine acoustic consulting, engineering, material procurement, and installation coordination to manage every aspect of noise and vibration control across all your projects.
By integrating each phase, we ensure solutions perform exactly as designed. The result is a smoother project experience, predictable outcomes, and acoustic environments that support customer needs, safety, and long-term reliability.
This integrated delivery model eliminates uncertainty, maintains consistent quality, and gives you confidence that your space will perform as intended.

A Strategic Partner, Not Just a Vendor
Whether you are looking to reduce operator noise exposure near heavy machinery or address residential complaints from surrounding neighborhoods, Memtech Acoustics helps you lead with confidence. Backed by 25+ years of practice, 2,000+ industrial projects completed nationwide, and 50+ years of combined engineering experience, Memtech Acoustics is trusted by industrial clients including Ford, General Motors, Magna, ABB, and NASA.
- Site measurements and data-driven analysis
- Root-cause identification
- Acoustic modeling and solution simulation
- Tailored solution designs
- Installation (or guided support)
- Final validation with documentation as required for compliance

Why Industrial Clients Choose Memtech Acoustics
- Engineered to Reduce Noise using a Cost-Effective Approach
Root-cause solutions, not cosmetic fixes. - Industrial Expertise You Can Trust
Field-tested across many manufacturing sectors. - Compliance Without Compromise
Reduce risk while staying productive. - A Partner Who Speaks Your Language
Clear, technical, and reliable communication. - Solutions That Last
Built to endure heat, vibration, and time. - Full-Service Project Delivery
Reduced complexity, fewer handoffs, smoother outcomes. - Local Accountability. Regional Reach.
Based in Michigan, supporting the Midwest and beyond.
Frequently Asked Questions (FAQs)
Let’s Engineer the Right Solution, Together.
Defensible Data From Testing Through Installed Controls
OSHA 29 CFR 1910.95 sets the permissible exposure limit, and the money you spend to meet it has to prove it worked. Memtech measures the TWA, engineers the insertion loss, and delivers a quantified report that holds up in front of a regulator, a customer, or your own board.
- Worker hearing, company liability, and a customer contract or permit all ride on the result.
- One accountable partner runs the full loop, from exposure testing to installed controls, no vendor handoffs.
- We produce measurable, defensible results on projects where other providers could not deliver the numbers.
Bring us the spec and the deadline. Contact Memtech to scope an assessment that produces numbers you can defend.